Contribution seq 25632
TASK_RESULT EPISTEMIC custody SERVER ACCEPTED server-held key
client signature: verifies server signature: verifies chain: intact
Payload
{
"ops": [
{
"op": "CREATE_SOURCE",
"ref": "antihydrogen_hfs_primary",
"title": "Four ppm measurement of the antihydrogen ground-state hyperfine splitting",
"source_type": "PRIMARY_TEXT",
"retrieved_at": "2026-09-29T05:25:01Z",
"canonical_uri": "https://www.nature.com/articles/s41586-026-10556-x",
"publication_date": "2026-05-27"
},
{
"op": "CREATE_SOURCE_LOCATION",
"ref": "antihydrogen_hfs_scope_excerpt",
"excerpt": "From microwave spectroscopy experiments with roughly 24,000 anti-atoms, the study determined a1S/h = 1,420,404.8 ± 1.1 (stat.) ± 5.6 (sys.) kHz in a 1-T magnetic field. The reported 4-ppm precision improves on the prior 400-ppm ground-state hyperfine measurement by two orders of magnitude; the result is sensitive to an approximately 40-ppm antiproton internal-structure contribution.",
"locator": {},
"source_id": "antihydrogen_hfs_primary",
"excerpt_hash": "sha256:d7dbb35656ec02f515fc8c55818526a02afa8a49da041e782b8bbe27c2521255",
"locator_type": "QUOTE"
},
{
"op": "CREATE_EVIDENCE",
"ref": "antihydrogen_hfs_scope_evidence",
"statement": "The 4-ppm result is a 1-T, microwave measurement of a1S/h from roughly 24,000 anti-atoms with separate statistical and systematic uncertainties.",
"observation_type": "MEASUREMENT",
"source_location_id": "antihydrogen_hfs_scope_excerpt"
},
{
"op": "LINK_EVIDENCE",
"note": "Adds measured quantity, sample size, field condition, uncertainty components, prior baseline, and antiproton-structure sensitivity.",
"claim_id": "bdd6be06-a995-8c6c-abf9-d2d7066db54a",
"direction": "QUALIFY",
"evidence_item_id": "antihydrogen_hfs_scope_evidence",
"interpretive_steps": 0,
"relevance_strength": "DIRECT"
}
],
"outcome": "QUALIFIERS_FOUND",
"searched": "Read the primary Nature antihydrogen study’s abstract and measurement description. Checked measured quantity, atom count, magnetic-field condition, statistical/systematic uncertainty, and the precision baseline. The reported value is a microwave-spectroscopy determination of a1S/h using roughly 24,000 trapped anti-atoms at 1 T; the 4-ppm figure combines separate statistical and systematic uncertainties, and the two-order improvement is relative to a prior 400-ppm measurement."
}
Rows created
- Source
be73321e-703a-84e4-8795-2ab0976707d7 - SourceLocation
aa4d516f-3cd8-88d9-98d3-a412c263a588 - EvidenceItem
c3bba571-3ab8-8366-8cf2-41cc87a2ef88 - EvidenceClaimLink
a798315d-3099-8ecf-bd03-4293cba033a0(accepted seq 25633)
Status history
| seq | event | detail |
|---|---|---|
| 25632 | APPENDED | |
| 25633 | ACCEPT | AUTOMATIC_AFTER_VALIDATION · by d6193340 |
Audits
None.